HP DSC 2+ — A High-Pressure Differential Scanning Calorimeter from Mettler-Toledo

High pressure can affect all chemical reactions and physical changes where there is a volume change. For quality control, process development or material testing, there is usually no alternative to DSC measurements under pressure.

  • Shorter analysis time — reactions are expedited by higher temperatures and pressures
  • Better interpretation — effects can be isolated by suppressing vaporization
  • Measurements under process conditions — practical reaction environments can be simulated

 

Sensor

Sensor. Image Credit: Mettler-Toledo International Inc.

HP DSC-Microscopy.

HP DSC-Microscopy. Image Credit: Mettler-Toledo International Inc.

HP DSC- Chemiluminescence.

HP DSC- Chemiluminescence. Image Credit: Mettler-Toledo International Inc.

PC 10.

PC 10. Image Credit: Mettler-Toledo International Inc.

Specifications

HP DSC 2+ — High-Pressure Differential Scanning Calorimeter

Source: Mettler-Toledo International Inc.

. .
Temperature range RT ... 500 °C / 700 °C
Heating rate 0.1…50 K/min
Pressure range 0 … 10 MPa (overpressure)
Gas flow freely selectable, accurate control of purge gas flow rates and total pressure with external controller
Atmospheres Measurements under different atmospheres: inert, oxidizing, reducing, reactive, e.g. nitrogen, oxygen, hydrogen, methyl bromide, ethylene, propylene, carbon dioxide, etc. There are certain restrictions for combustible and toxic gases
Trade Name DSC

 

Innovative Technology

Features and Benefits of the HP DSC 2+

Shorter analysis times — higher temperature and pressure expedite reactions

HP DSC 2+ — A High-Pressure Differential Scanning Calorimeter from Mettler-Toledo

Image Credit: Mettler-Toledo International Inc. 

Measurements under process conditions — practical reaction environments can be simulated.

HP DSC 2+ — A High-Pressure Differential Scanning Calorimeter from Mettler-Toledo

Image Credit: Mettler-Toledo International Inc. 

Better interpretation — effects can be isolated by suppressing vaporization.

HP DSC 2+ — A High-Pressure Differential Scanning Calorimeter from Mettler-Toledo

Image Credit: Mettler-Toledo International Inc. 

Higher gas concentrations — the reaction rate of heterogeneous reactions with gases is increased.

HP DSC 2+ — A High-Pressure Differential Scanning Calorimeter from Mettler-Toledo

Image Credit: Mettler-Toledo International Inc. 

Measurements under unique atmospheres — oxidative, oxygen-free conditions or measurements with combustible or poisonous gases can be made.

HP DSC 2+ — A High-Pressure Differential Scanning Calorimeter from Mettler-Toledo

Image Credit: Mettler-Toledo International Inc. 

Rugged sensor with high resolution and excellent sensitivity — very weak effects and exceptional temperature resolution of close-lying effects can be measured. 

HP DSC 2+ — A High-Pressure Differential Scanning Calorimeter from Mettler-Toledo

Image Credit: Mettler-Toledo International Inc. 

Other Equipment by this Supplier